Re: AP900 CP2 Issue
I have only ever seen low voltage uncontrolled slewing with
the CP2. I have never seen it with the CP3 or CP4.
Both the CP3 and CP4 have low voltage detection and slew
lockout features. That's one of the things that will trigger an amber
indicator LED on those controllers. As will detecting a motor
stall.
-Christopher Erickson
Observatory engineer Summit Kinetics
From: ap-gto@... [mailto:ap-gto@...] Sent: Sunday, August 6, 2017 6:21 AM To: ap-gto@... Subject: Re: [ap-gto] AP900 CP2 Issue I have had this happen and in my case, AP900GTO CP2 it was the pins
in the power socket needing to be gently spread back so they made proper
contact.
Stuart On Sun, Aug 6, 2017 at 1:35 AM, 'Joseph Zeglinski' J.Zeglinski@... [ap-gto] <ap-gto@...> wrote:
Stuart Heggie
|
|