Re: GTO1100 CP4: No sync with mount after plate solving possible
Ray Gralak
Hi Thomas,
toggle quoted messageShow quoted text
I think the problem is that the locality settings for your computer needs to have the "." and "," reversed, as you can see in an example command below: 0053974 2017-07-06 02:03:40.925: Info, ProcessVPortCommand, RX from VPort 0: :Sr22:46:55,0# The ":Sr22:46:55,0" should be ":Sr22:46:55.0". Best regards, -Ray Gralak Author of APCC (Astro-Physics Command Center): http://www.astro-physics.com/index.htm?products/accessories/software/apcc/apcc Author of PEMPro: http://www.ccdware.com Author of Astro-Physics V2 ASCOM Driver: http://www.gralak.com/apdriver Author of PulseGuide: http://www.pulseguide.com Author of Sigma: http://www.gralak.com/sigma
-----Original Message-----
|
|